Region: AU  CN Asia

Aluminium Grating Load Tables

Aluminium grating

Webforge Aluminium Grating Deflection Data



Utilise the following table to select the appropriate grating profile for your application and project specifications.
CORRECT SPAN
CORRECT




INCORRECT SPAN
INCORRECT

ALUMINIUM GRATING LOAD TABLE
Spans in the darker shading (to the left of the heavy line) have a deflection of less than 5mm for a 4kPa uniformly distributed load.
Mass shown are untreated and unbanded.
Load deflection tables are arranged in rising strength order.  See the 4kPa, 5mm deflection column.
U = Superimposed uniformly distributed load in kPa (100kg/m2 = 0.98kPa)
D = deflection in mm for the load U
Assumptions for load capacity is on single spans
Based on allowable stress of 115 mPa for aluminium.
Recommended minimum landing = grating depth greater than or equal to 25mm.

Webforge Asia Contact Us
Webforge Asia Load Tables
Webforge Asia Request A Quote


Webforge operates throughout the Asia Pacific region in locations such as  India, New ZealandSingapore, Philippines, Indonesia, Thailand, Vietnam, Malaysia, China, and Australia.